Ambient Weather WS-108 Bedienungsanleitung Seite 43

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 46
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 42
Version 1.1 ©Copyright 2014, Ambient LLC. All Rights Reserved. Page 43
Problem
Solution
Move the display console around electrical noise generating devices, such as
computers, TVs and other wireless transmitters or receivers.
Outdoor sensor array
does not communicate
to the display console.
The sensor array may have initiated properly and the data is registered by the
console as invalid, and the console must be reset. The reset button is next
to the LED, near the mounting point on the sensor array, as shown in Figure
11.
With an open ended paperclip, press the reset button for 3 seconds to
completely discharge the voltage.
Take out the batteries and wait one minute, while covering the solar panel
to drain the voltage.
Put batteries back in and resync with console by powering down and up
the console with the sensor array about 10 feet away.
Bring the sensor array inside the house (you can disconnect it from the rest
of the sensors). The LED next to the battery compartment will flash every 16
seconds. If the LED is not flashing every 16 seconds…
Replace the batteries in the outside sensor array. Non-rechargeable batteries
are OK for testing purposes.
If the batteries were recently replaced, check the polarity. If the sensor is
flashing every 48 seconds, proceed to the next step.
There may be a temporary loss of communication due to reception loss
related to interference or other location factors,
or the batteries may have been changed in the sensor array and the console
has not been reset. The solution may be as simple as powering down and
up the console.
Replace the batteries in the outside sensor array. Non-rechargeable batteries
are OK for testing purposes.
With the sensor array and console 10 feet away from each other, remove AC
power from the display console and wait 10 seconds. Re-connect power.
Temperature sensor
reads too high in the
day time.
Make certain that the sensor array is not too close to heat generating sources
or strictures, such as buildings, pavement, walls or air conditioning units.
Use the calibration feature to offset installation issues related to radiant heat
sources. Reference 6.5.
Absolute pressure
does not agree with
official reporting
station
You may be viewing the relative pressure, not the absolute pressure.
Select the absolute pressure. Make sure you properly calibrate the sensor to
an official local weather station. Reference Section 6.5 for details.
Rain gauge reports
rain when it is not
raining
An unstable mounting solution (sway in the mounting pole) may result in the
tipping bucket incorrectly incrementing rainfall. Make sure you have a
stable, level mounting solution.
Sunrise and sunset is
incorrect
Make certain your time zone, longitude and latitude are set properly.